Freescale Semiconductor /MKV56F24 /HSADC0 /STAT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as STAT

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)CALONA 0 (0)CALONB 0 (0)DUMMYA 0 (0)DUMMYB 0 (0)EOCALIA 0 (0)EOCALIB 0 (0)HLMTI 0 (0)LLMTI 0 (0)ZCI 0 (0)EOSIA 0 (0)EOSIB 0 (0)CIPB 0 (0)CIPA

CIPA=0, HLMTI=0, EOCALIA=0, DUMMYB=0, LLMTI=0, DUMMYA=0, CIPB=0, EOSIB=0, EOSIA=0, EOCALIB=0, CALONB=0, CALONA=0, ZCI=0

Description

HSADC Status Register

Fields

CALONA

HSADCA Calibration execution status

0 (0): Calibration is not running

1 (1): ADCA is running calibration conversions

CALONB

HSADCB Calibration execution status

0 (0): Calibration is not running

1 (1): ADCB is running calibration conversions

DUMMYA

Dummy conversion running on HSADCA

0 (0): Dummy conversion is not running

1 (1): Dummy conversion is running on ADCA

DUMMYB

Dummy conversion running on HSADCB

0 (0): Dummy conversion is not running

1 (1): Dummy conversion is running on ADCB

EOCALIA

End of Calibration on ADCA Interrupt

0 (0): Calibration is not finished.

1 (1): Calibration is finished on ADCA. The IRQ occurs if CALIB[EOCALIEA] is asserted.

EOCALIB

End of Calibration on ADCB Interrupt

0 (0): Calibration is not finished.

1 (1): Calibration is finished on ADCB. The IRQ occurs if CALIB[EOCALIEB] is asserted.

HLMTI

High Limit Interrupt

0 (0): No high limit interrupt request

1 (1): High limit exceeded, IRQ pending if CTRL1[HLMTIE] is set

LLMTI

Low Limit Interrupt

0 (0): No low limit interrupt request

1 (1): Low limit exceeded, IRQ pending if CTRL1[LLMTIE] is set

ZCI

Zero Crossing Interrupt

0 (0): No zero crossing interrupt request

1 (1): Zero crossing encountered, IRQ pending if CTRL1[ZCIE] is set

EOSIA

End of Scan Interrupt

0 (0): A scan cycle has not been completed, no end of scan IRQ pending

1 (1): A scan cycle has been completed, end of scan IRQ pending

EOSIB

End of Scan Interrupt

0 (0): A scan cycle has not been completed, no end of scan IRQ pending

1 (1): A scan cycle has been completed, end of scan IRQ pending

CIPB

Conversion in Progress

0 (0): Idle state

1 (1): A scan cycle is in progress. The HSADC will ignore all sync pulses or start commands

CIPA

Conversion in Progress

0 (0): Idle state

1 (1): A scan cycle is in progress. The HSADC will ignore all sync pulses or start commands

Links

() ()